Error Code CL E
Low-Side Cycle Leakage / Sealed System Problem
Moderate
Address soon - your appliance may not work properly
How to Fix
- 1
1. Use LG SVC App Step 1 or temperature gun to diagnose compressor vs. sealed system issue.
- 2
2. Check voltage at PCB to rule out PCB problem.
- 3
3. Check low/high side pressures and equalization return time.
- 4
4. If equalization time exceeds 15 minutes, sealed system is blocked.
- 5
5. If equalization pressure is below 40 psi, likely a refrigerant leak.
- 6
6. Charge with N2 or R134a to locate leak.
- 7
7. Check low-pressure side parts (evaporator, suction pipe) for leaks first.
- 8
8. If no low-side leak found, check high-pressure side parts (condenser, drier).
- 9
9. Replace leaking parts along with drier.
- 10
10. If compressor is faulty, replace compressor and drier.
- 11
11. Error clears automatically when freezer reaches 14°F.
- 12
12. If system is normal but error persists, press F key + R key 3 times with door open to force-clear.
This Error Applies To
LG LHFS28XBS Series Refrigerators