Abnormal F-Room Icemaker Kit Operation
Moderate
Address soon - your appliance may not work properly
How to Fix
- 1
1. Identify symptom: harvest failure (upper heater) or slow-melting heating / cloudy ice (lower heater).
- 2
2. Check upper heater resistance — should be 14.1-16.3 ohm. If open, replace upper heater.
- 3
3. Check lower heater resistance — should be 14.1-16.3 ohm. If open, replace lower heater.
- 4
4. If heater resistances are normal, check icemaker tray position and carry out test mode using test switch.
- 5
5. If no issue with heaters or mechanism, check Main PCB and harness from Main PCB to icemaker.
- 6
6. If icemaker tray stays open for more than 1 minute or never stops movement, replace icemaker.
This Error Applies To
LG LHFS28XBS Series Refrigerators
Service manual exact match: LHFS28XBS/02