Error Code E Rt
Room Temperature Sensor Error — short or disconnection of room temperature sensor
Moderate
Address soon - your appliance may not work properly
Also displayed as: E Rt
How to Fix
- 1
Step 1: Check room temperature sensor connector for disconnection or poor contact.
- 2
Step 2: Measure sensor resistance and compare to expected values at ambient temperature.
- 3
Step 3: If sensor reads 0Ω (short) or OL (open), replace the room temperature sensor.
- 4
Step 4: If sensor passes, replace the Main PCB.
This Error Applies To
LG LRFCS29D6S Series Refrigerators
Related Error Codes
Icing Sensor Error — short or disconnection of icing sensor (ice maker sensor). Note: E IS displayed without user input is the error of the Icing Sensor.
Refrigerator Sensor Error — short or disconnection of Refrigerator Sensor
Freezer Sensor Error — short or disconnection of Freezer Sensor
Defrost Sensor Error — short or disconnection of Defrost Sensor
Freezer Fan (BLDC) Error — feedback signal not received from freezer fan motor within 65 seconds
Communication Error — communication failure between Main PCB MICOM and Display PCB MICOM
Defrost Heater Error — defrost heater or defrost control circuit failure
Condenser Fan (BLDC) Error — feedback signal not received from condenser fan motor within 65 seconds