Error Code F dH
Defrost heater error — defrost sensor did not reach 40°F (5°C) within 80 minutes after defrost start
Moderate
Address soon - your appliance may not work properly
Also displayed as: F dH
How to Fix
- 1
Check the door gasket for damage or gaps that could allow warm air infiltration causing excessive frost accumulation. Replace door gasket if damaged.
- 2
Enter Test Mode 1 (press Main PCB test button once): measure CON9 Pin 5 ~ Pin 13 voltage. Should be 0V in Test Mode 1 (heater off state). If not 0V, replace Main PCB.
- 3
Enter Test Mode 3 (press test button three times): measure CON9 Pin 5 ~ Pin 13 voltage. Should be 112–116V when defrost is forced. If voltage is absent, replace Main PCB.
- 4
Measure Fuse-M resistance (CON9 pins): should read 0 Ω. If open (infinite), replace Fuse-M.
- 5
Measure defrost heater resistance: F1 heater should be 62–70 Ω; F2 heater 144–167 Ω. Infinite resistance indicates open heater — replace heater assembly.
- 6
Measure defrost sensor resistance at CON8 Pin 26 ~ Pin 25: should be approximately 22kΩ at room temperature. If open or shorted, replace defrost sensor.
- 7
If all components test good and voltage is present, explain to customer (possible temporary condition from extended door opening).
This Error Applies To
LG LRFGC2706S Series Refrigerators
Related Error Codes
Humidity sensor error — short-circuit or disconnection of humidity sensor
Freezer icemaker sensor error — short-circuit or disconnection of ice maker sensor
Freezer ice maker kit defect — malfunction of ice maker motor
Freezer sensor error — short-circuit or disconnection of freezer sensor
Defrost sensor error — short-circuit or disconnection of freezer defrost sensor
Freezer BLDC fan motor error — no feedback signal from fan motor for more than 65 seconds
Refrigerator sensor error — short-circuit or disconnection of refrigerator sensor
Condenser (machine room) BLDC fan motor error — no feedback signal for more than 65 seconds