Error Code F dS
Defrost Sensor Error — short or disconnection of defrost sensor
Moderate
Address soon - your appliance may not work properly
Also displayed as: F dS
How to Fix
- 1
Step 1: Check if connector is disconnected or loose between Main PCB, defrost controller, and sensor. If yes, reconnect or repair the connector.
- 2
Step 2: Measure sensor resistance. If resistance is 0 Ω (shorted) or infinite Ω (open), replace the sensor.
- 3
Step 3: Check sensor resistance at measured ambient temperature against the resistance table (CON7, 19th pin to 22nd pin). Values range from 38 kΩ at 23°F to 16 kΩ at 59°F.
- 4
Step 4: If resistance is normal for the current temperature, explain to customer that unit is operating correctly.
- 5
Step 5: If resistance is abnormal but sensor and connector are good, replace Main PCB.
This Error Applies To
LG LRFWS2906 Series Refrigerators
Related Error Codes
Room Temperature Sensor Error — short or disconnection of room temperature sensor
Icing Sensor Error — short or disconnection of icing sensor (ice maker sensor). Note: E IS displayed without user input indicates icing sensor fault; E IS generated by user action (pressing test switch within 1 week of ice twisting) indicates ice maker mechanical issue.
Defrost Heater Error — defrost temperature does not rise above 47°F (8°C) within expected time; caused by door gasket failure, defrost heater open, blown Fuse-M, or poor PCB relay
Freezer Fan (BLDC) Error — abnormality of BLDC fan motor for freezer; motor does not respond after 3 retry attempts (each attempt: 15s on, 10s off)
Condenser Fan (BLDC) Error — abnormality of BLDC fan motor for mechanical/condenser room
Communication Error — loss of communication between Main PCB MICOM and Display PCB MICOM; also between Transmitter and Receiver
Low Side Cycle Leakage — detected by low amplitude cycle variation; caused by low-side refrigerant leak, bad compressor, or extended door-open condition
High Side Cycle Leakage — detected by high amplitude cycle variation; caused by high-side refrigerant leak, restriction in system, bad compressor, or bad valve