LG Refrigerators

Error Code E rt

Ambient (Room) Temperature Sensor Abnormal — Room temperature sensor short or open

Moderate

Address soon - your appliance may not work properly

Also displayed as: E rt

How to Fix

  1. 1

    Check CON7 connector (pins 17~18) between Main PCB and ambient sensor for loose or disconnected condition.

  2. 2

    If connector is loose/disconnected, reconnect or repair the connector.

  3. 3

    Measure ambient sensor resistance at CON7 pins 17~18: 0 ohm = short (replace sensor), Open/infinity = open (replace sensor).

  4. 4

    Compare measured resistance to temperature chart: -5°C=38k, 0°C=30k, 5°C=24k, 10°C=19.5k, 15°C=16k ohms.

  5. 5

    If resistance is normal, explain to customer.

  6. 6

    If sensor is verified good but error persists, replace the Main PCB.

This Error Applies To

LG LRSOC2306 Series Refrigerators

Service manual exact match: LRSOC2306SService manual exact match: LRSOC2306VService manual exact match: LRSOC2306BService manual exact match: LRSOC2306W