Error Code PE
Pressure Sensor Error
Moderate
Address soon - your appliance may not work properly
What This Means
Pressure sensor assembly out of order; Water level frequency consistently below 10 kHz or over 30 kHz; Pressure sensor connector broken or loose; Pressure sensor resistance out of range (pin 1 to pin 3 should be 21-23 Ohm ±10%); Air chamber and tube clogged
How to Fix
- 1
Confirm PE is displayed. Note: PE will NOT disappear when START/PAUSE is pressed — it does not enter pause mode
- 2
Check if pressure sensor connector is broken or loose. Reconnect or repair if so
- 3
Measure resistance of pressure sensor (pin 1 to pin 3, should be 21-23 Ohm ±10%). Replace pressure switch if out of range
- 4
Check if AIR CHAMBER and tube are clogged. Fix air chamber and remove foreign material if clogged
- 5
If all checks pass, replace MAIN PWB ASSEMBLY
This Error Applies To
LG WM8980H Series Washers (2019) (2019–present)