Error Code 3CA
The heat pump compressor motor isn't working
Critical
Stop using immediately - risk of damage or safety issue
Also displayed as: 3CA / 3CA1 / 3CA2 / 3CA3 / 3CA4 / 3CA5 / 3CA6 / 3CA7 / 3CA8
What This Means
Compressor motor fault; Compressor Inverter PBA fault; Incorrect wiring connections to compressor; Compressor mechanical failure
What actually causes this:
The compressor motor in a heat pump dryer has failed or encountered an electrical issue.
First Thing to Check
Unplug the dryer for 5 minutes, then plug it back in and try again.
Parts Involved
How to Fix
- 1
1. Check the connector terminal connections and contacts on compressor
- 2
2. Check whether there is the motor power cable and power connector in Compressor Inverter PBA
- 3
3. Check whether the compressor motor is damaged
- 4
4. If the Compressor Inverter PBA is faulty, replace the PBA
This Error Applies To