Samsung Dryers2024–present

Error Code tCA

A fifth temperature sensor is reading incorrectly

Moderate

Address soon - your appliance may not work properly

Also displayed as: tCA

What This Means

Thermistor 5 resistance out of range (open or shorted); Wiring harness fault between Thermistor 5 and PBA

What actually causes this:

One of the dryer's multiple temperature sensors has failed or become disconnected.

First Thing to Check

Clean the lint screen and check the exhaust vent for blockages.

Parts Involved

Thermistor 5

How to Fix

  1. 1

    1. Check Thermistor 5 resistance with ohmmeter

  2. 2

    2. Inspect wiring harness to Thermistor 5 for loose or damaged connections

  3. 3

    3. If resistance is out of range, replace Thermistor 5

This Error Applies To

Samsung DV25B6800H Series Dryers (2024) (2024–present)