Samsung Dryers2024–present

Error Code tC8

A fourth temperature sensor is reading abnormally

Moderate

Address soon - your appliance may not work properly

Also displayed as: tC8

What This Means

Thermistor 4 resistance out of range (open or shorted); Wiring harness fault between Thermistor 4 and PBA

What actually causes this:

One of the dryer's multiple temperature sensors has failed or its connection is loose.

First Thing to Check

Clean the lint screen and check the exhaust vent for blockages.

Parts Involved

Thermistor 4

How to Fix

  1. 1

    1. Check Thermistor 4 resistance with ohmmeter

  2. 2

    2. Inspect wiring harness to Thermistor 4 for loose or damaged connections

  3. 3

    3. If resistance is out of range, replace Thermistor 4

This Error Applies To

Samsung DV25B6800H Series Dryers (2024) (2024–present)

Service manual exact match: DV25B6900HW/A2Service manual exact match: DV90N62632X/EUService manual exact match: DV25B6800HW/ACService manual exact match: DV25B690*H*Service manual exact match: DV25B6800H*Service manual exact match: DV22N6850*