Samsung Dryers2024–present

Error Code AC6

The drum motor controller isn't communicating properly

Critical

Stop using immediately - risk of damage or safety issue

Also displayed as: AC6

What This Means

Incorrect wire connections between main and inverter PBAs; Disconnected wires between main and inverter PBAs; Main PBA communication circuit fault; Inverter PBA communication circuit fault

What actually causes this:

An internal communication failure between the main control board and the drum motor controller.

First Thing to Check

Unplug the dryer for 2 minutes, then plug it back in — this resets the electronics.

Parts Involved

Main PBAInverter PBA (Drum)Wire Harness

How to Fix

  1. 1

    1. Check wire connections and terminal contacts between main and inverter PBAs

  2. 2

    2. Check for disconnected wires

  3. 3

    3. If the main or Inverter PBA communication circuit is faulty, replace it

This Error Applies To

Samsung DV25B6800H Series Dryers (2024) (2024–present)

Service manual exact match: DV25B6900HW/A2Service manual exact match: DV90N62632X/EUService manual exact match: DV25B6800HW/ACService manual exact match: DV25B690*H*Service manual exact match: DV25B6800H*Service manual exact match: DV22N6850*