Samsung Dryers2024–present

Error Code HC5

The heat pump compressor has stopped working

Critical

Stop using immediately - risk of damage or safety issue

Also displayed as: HC5

What This Means

Repeated compressor overheating detected by Thermistor 5; Compressor mechanical fault; Condenser blockage causing heat buildup; Refrigerant system issue

What actually causes this:

The compressor that generates heat in a heat pump dryer has shut down, often due to an internal fault.

First Thing to Check

Unplug the dryer for 5 minutes, then plug it back in and try again.

Parts Involved

CompressorThermistor 5Condenser

How to Fix

  1. 1

    1. Check Compressor operation and condition

  2. 2

    2. Check Thermistor 5 resistance

  3. 3

    3. Clean the condenser thoroughly

  4. 4

    4. Verify refrigerant system integrity

  5. 5

    5. If compressor keeps overheating, replace compressor assembly

This Error Applies To

Samsung DV25B6800H Series Dryers (2024) (2024–present)

Service manual exact match: DV25B6900HW/A2Service manual exact match: DV90N62632X/EUService manual exact match: DV25B6800HW/ACService manual exact match: DV25B690*H*Service manual exact match: DV25B6800H*Service manual exact match: DV22N6850*