Error Code HC5
The heat pump compressor has stopped working
Critical
Stop using immediately - risk of damage or safety issue
Also displayed as: HC5
What This Means
Repeated compressor overheating detected by Thermistor 5; Compressor mechanical fault; Condenser blockage causing heat buildup; Refrigerant system issue
What actually causes this:
The compressor that generates heat in a heat pump dryer has shut down, often due to an internal fault.
First Thing to Check
Unplug the dryer for 5 minutes, then plug it back in and try again.
Parts Involved
How to Fix
- 1
1. Check Compressor operation and condition
- 2
2. Check Thermistor 5 resistance
- 3
3. Clean the condenser thoroughly
- 4
4. Verify refrigerant system integrity
- 5
5. If compressor keeps overheating, replace compressor assembly
This Error Applies To
Samsung DV25B6800H Series Dryers (2024) (2024–present)
Related Error Codes
A secondary temperature sensor is giving bad readings
A fourth temperature sensor is reading abnormally
The compressor temperature sensor detected a problem
Your dryer's temperature sensor isn't reading correctly
A third temperature sensor is giving incorrect readings
A fifth temperature sensor is reading incorrectly
The drum motor temperature sensor detected a problem
A button on the control panel is stuck or shorted