Samsung Dryers2024–present

Error Code tC

Your dryer's temperature sensor isn't reading correctly

Moderate

Address soon - your appliance may not work properly

Also displayed as: tC

What This Means

Clogged lint screen restricting airflow; Restricted vent system causing abnormal temperature readings; Thermistor1 resistance out of range (open or shorted)

What actually causes this:

Usually a clogged lint screen or blocked exhaust vent — restricted airflow causes the sensor to misread temperatures.

First Thing to Check

Pull out the lint screen and clean off all the lint, then check that your exhaust vent hose isn't kinked or blocked.

Parts Involved

Thermistor (Temperature Sensor)Lint ScreenExhaust Vent

How to Fix

  1. 1

    1. Check for a clogged lint screen

  2. 2

    2. Check if the vent system is restricted

  3. 3

    3. Measure Thermistor1 resistance: should be 10K ohm at 25 degrees C (77 degrees F)

  4. 4

    4. If resistance is out of range, replace the thermistor

  5. 5

    5. If this information code remains, contact a Samsung service center

This Error Applies To

Samsung DV25B6900E Series Dryers (2024) (2024–present)

Service manual exact match: DV25B6900EX/ACService manual exact match: DV25B6900E*Service manual exact match: DV25B6900EW/A2

Need more help with your Samsung dryers?