Samsung Dryers

Error Code tC5

A secondary temperature sensor is giving bad readings

Moderate

Address soon - your appliance may not work properly

Also displayed as: tC5

What This Means

Clogged lint screen restricting airflow; Restricted vent system causing abnormal temperature readings; Thermistor2 resistance out of range (open or shorted)

What actually causes this:

Similar to the main temperature sensor error — usually caused by lint buildup restricting airflow, or the sensor itself has worn out.

First Thing to Check

Clean the lint screen thoroughly and make sure the exhaust vent path is clear.

Parts Involved

Thermistor 2 (Temperature Sensor)Lint Screen

How to Fix

  1. 1

    1. Check for a clogged lint screen and clean it

  2. 2

    2. Check if the vent system is restricted or blocked

  3. 3

    3. Check the thermistor2 resistance

  4. 4

    4. If thermistor resistance is out of range, replace the thermistor

This Error Applies To

Samsung DV55CG7 Series Dryers

Service manual exact match: DVE55CG7500EA3Service manual exact match: DVG55CG7500EA3Service manual exact match: DVE55CG7100VA3Service manual exact match: DVE55CG7100DA3Service manual exact match: DVE55CG7105VACService manual exact match: DVG55CG7500EService manual exact match: DVG55CG7100WService manual exact match: DVG55CG7100V+2 more

Need more help with your Samsung dryers?