Error Code tC5

A secondary temperature sensor is giving bad readings

Moderate

Address soon - your appliance may not work properly

Also displayed as: tC5

What This Means

Clogged lint screen restricting airflow and causing abnormal temperature readings; Restricted vent system causing heat buildup; Thermistor 2 resistance out of range (open or shorted)

What actually causes this:

Similar to the main temperature sensor error — usually caused by lint buildup restricting airflow, or the sensor itself has worn out.

First Thing to Check

Clean the lint screen thoroughly and make sure the exhaust vent path is clear.

Parts Involved

Thermistor 2Lint Screen

How to Fix

  1. 1

    1. Check and clean the lint screen

  2. 2

    2. Inspect the exhaust vent system for restrictions or blockages

  3. 3

    3. Measure thermistor 2 resistance (gas model thermistor: 238.23K ohm at 25 degrees C)

  4. 4

    4. If thermistor resistance is out of range, replace the thermistor

Parts Commonly Needed for This Error

OEM part numbers confirmed by retailers

This Error Applies To

Samsung DVE45T6005 Series Dryers (2024) (2024–present)

Service manual exact match: DVE45T6005W/ACService manual exact match: DVG45T6005W/ACService manual exact match: DVE45T6000W/A3Service manual exact match: DVG45T6000W/A3Service manual exact match: DVE45T6200W/A3Service manual exact match: DVG45T6200W/A3Service manual exact match: DVE45R6100*Service manual exact match: DVG45R6100*+2 more