Samsung Dryers2019–present

Error Code AC

The dryer's internal parts aren't communicating properly

Critical

Stop using immediately - risk of damage or safety issue

Also displayed as: AC

What This Means

Faulty Main PBA (main control board); Faulty SUB PBA (display board); Damaged or loose wire harness between Main PBA and SUB PBA

What actually causes this:

A loose wire connection between the control board and display, or a power surge scrambled the electronics.

First Thing to Check

Unplug the dryer for 2 minutes, then plug it back in — this resets the electronics.

Parts Involved

Main PBA (Main PCB)SUB PBA (Display PCB)Wire Harness

How to Fix

  1. 1

    1. First check the PCB and wire harness connection between Main PBA and SUB PBA

  2. 2

    2. Inspect wire harness for pinched, cut, or corroded wires

  3. 3

    3. Replace the PCB if the problem persists

  4. 4

    4. Replace SUB PBA first (more commonly at fault), then Main PBA if error persists

Parts Commonly Needed for This Error

OEM part numbers confirmed by retailers

This Error Applies To

Samsung DVE50T5300 Series Dryers (2019) (2019–present)

Service manual exact match: DVE50R5400*/A3Service manual exact match: DVG50R5400*/A3Service manual exact match: DVE50R5200*/A3Service manual exact match: DVE50T5300C/A3Service manual exact match: DVG50T5300C/A3Service manual exact match: DVE50R5400*Service manual exact match: DVG50R5400*Service manual exact match: DVG50R5200*+2 more

Need more help with your Samsung dryers?