Gas sensor output voltage out of acceptable operating range

Moderate

Address soon - your appliance may not work properly

Also displayed as: C-10

What This Means

Gas sensor disconnected; Gas sensor wire not connected properly; Gas sensor failure; Main PCB failure

What actually causes this:

Sensor contamination, wire corrosion, connector looseness, or sensor aging

First Thing to Check

Inspect gas sensor housing connector and reseat connection at Main PCB (CN301)

Parts Involved

Gas SensorMain PCBConnectors

How to Fix

  1. 1

    Check gas sensor part and housing connection

  2. 2

    Verify sensor connector at Main PCB

  3. 3

    Check sensor wiring for damage

  4. 4

    Test sensor output voltage changes with humidity/temperature