Error Code C-10
Gas sensor output voltage out of acceptable operating range
Moderate
Address soon - your appliance may not work properly
Also displayed as: C-10
What This Means
Gas sensor disconnected; Gas sensor wire not connected properly; Gas sensor failure; Main PCB failure
What actually causes this:
Sensor contamination, wire corrosion, connector looseness, or sensor aging
First Thing to Check
Inspect gas sensor housing connector and reseat connection at Main PCB (CN301)
Parts Involved
How to Fix
- 1
Check gas sensor part and housing connection
- 2
Verify sensor connector at Main PCB
- 3
Check sensor wiring for damage
- 4
Test sensor output voltage changes with humidity/temperature
This Error Applies To
Samsung DOC30P977D Series Ovens & Ranges
Related Error Codes
Broil heating element not energizing during self-test
Partition configuration changed during active cooking cycle
Cooling motor not responding to control signals
Loss of communication between main control and touch display panel
Drain system unable to evacuate water within time limit
Loss of communication between main control board and sub control board
Temperature sensor circuit is open - no resistance reading possible
Main control board temperature sensor reads excessive heat