Error Code C-30
Temperature sensor internal to Main PCB is not functioning
Critical
Stop using immediately - risk of damage or safety issue
Also displayed as: C-30
What This Means
Internal PCB sensor disconnected; PCB component failure; Internal wire break on PCB
What actually causes this:
Manufacturing defect, heat damage, or component failure
First Thing to Check
Confirm error persists after power cycle
Parts Involved
How to Fix
- 1
Disconnect power
- 2
Open back cover to access Main PCB
- 3
Visually inspect PCB for damaged sensor component