Error Code C-20
Temperature sensor failure - open circuit
Critical
Stop using immediately - risk of damage or safety issue
Also displayed as: C-20
What This Means
Loose connector at main PCB; Loose connector at sensor; Faulty temperature sensor; Damaged or broken wire harness
What actually causes this:
Wiring disconnected, sensor failed, or PCB connector problem
First Thing to Check
Verify connector CN320 at main PCB is fully seated and check sensor resistance
Parts Involved
How to Fix
- 1
Check whether connector at the main pcb has been inserted
- 2
Check whether connector at the sensor has been inserted
- 3
Measure sensor resistance (should be 1080Ω at room temperature)
- 4
Check the connecting condition of harness between oven sensor and CN320 of main PCB
- 5
Measure resistance of connector CN320 (Open: ∞Ω, Short: under 10Ω)
This Error Applies To
Samsung DOP36C86DL Series Ovens & Ranges
Related Error Codes
PCB over-temperature condition
Steam temperature sensor failure
Steam drain system failure - water not draining
Door lock mechanism failure
Temperature overshoot - sensor or control failure
Temperature probe failure - short circuit
Touch panel communication failure
Control board communication failure