Error Code C-23
Probe temperature sensor has short circuit
Critical
Stop using immediately - risk of damage or safety issue
Also displayed as: C-23
What This Means
Meat probe short circuit; Damaged probe wire or terminal; Failed probe connector
What actually causes this:
Moisture intrusion on probe, damaged probe element, or faulty connector
First Thing to Check
Measure meat probe resistance with probes disconnected from control
Parts Involved
How to Fix
- 1
Disconnect power and probe harness from control
- 2
Measure probe resistance: should be 50 kOhms at room temperature
- 3
Check for damaged terminal or wire on harness
- 4
Measure resistance of meat probe connector on main PCB (Normal: 10-11 kOhms)
This Error Applies To
Samsung DOP36M94DL Series Ovens & Ranges
Related Error Codes
Temperature sensor open circuit detected
PCB internal temperature abnormally high or sensor shorted
Temperature regulation failure causing excessive oven temperature
Inter-PCB communication link failure detected
Touch screen panel communication with main control board lost
Door locking mechanism failed to engage or disengage
Main PCB internal temperature sensor failed