Error Code E-83
PCB-to-PCB communication failure
Critical
Stop using immediately - risk of damage or safety issue
Also displayed as: E-83
What This Means
Main PCB CN201 connector disconnection; Sub PCB TE400 connector disconnection; Short circuit in communication line; Defective main PCB; Defective sub PCB
What actually causes this:
Loose connector, broken communication wire, or PCB microprocessor failure preventing proper communication
First Thing to Check
Verify main PCB CN201 and sub PCB TE400 connectors are fully seated and not bent
Parts Involved
How to Fix
- 1
Check if connector CN201 on main PCB is properly inserted
- 2
Check if connector TE400 on sub PCB is properly inserted
- 3
If connectors are secure, check for short circuit between pins on TE400 and CN201
- 4
If no short circuit found, replace sub PCB then main PCB if needed
This Error Applies To
Samsung NE58F9 Series Ovens & Ranges (2013) (2013–present)