PCB temp sensor opened (PCB temperature sensor circuit open)

Moderate

Address soon - your appliance may not work properly

What This Means

Sensor connection loose; Sensor resistance out of range; Main PCB holder connection loose; Defective Main PCB

How to Fix

  1. 1

    Disconnect power and open back cover

  2. 2

    Remove PCB Main from holder PCB

  3. 3

    Measure sensor resistance (normal: 5.4 kohms)

  4. 4

    Check sensor connection on Main PCB

  5. 5

    Replace PCB Main if resistance abnormal