Samsung Ovens & Ranges
Error Code C-30
PCB temp sensor opened (PCB temperature sensor circuit open)
Moderate
Address soon - your appliance may not work properly
What This Means
Sensor connection loose; Sensor resistance out of range; Main PCB holder connection loose; Defective Main PCB
How to Fix
- 1
Disconnect power and open back cover
- 2
Remove PCB Main from holder PCB
- 3
Measure sensor resistance (normal: 5.4 kohms)
- 4
Check sensor connection on Main PCB
- 5
Replace PCB Main if resistance abnormal
This Error Applies To
Samsung NE59J7650W Series Ovens & Ranges
Service manual exact match: NE59N6650SG/AAService manual exact match: NE59R6631SG/AAService manual exact match: NE59J7650WSService manual exact match: NE59N6650SG