PCB temperature sensor opened
Moderate
Address soon - your appliance may not work properly
What This Means
NTC sensor disconnected; Temperature sensor harness issue
How to Fix
- 1
Disconnect power, open back cover
- 2
Remove main PCB from holder
- 3
Measure NTC sensor located on back of PCB resistance
- 4
If problems found, replace main PCB
This Error Applies To