PCB temperature sensor opened

Moderate

Address soon - your appliance may not work properly

What This Means

PCB NTC sensor failure; PCB damage; Main PCB failure

How to Fix

  1. 1

    Disconnect power and open back cover

  2. 2

    Remove PCB Main from holder

  3. 3

    Measure NTC sensor resistance on backside of PCB (Normal: 3.8KΩ at room temperature)

  4. 4

    If abnormal, replace PCB Main