Error Code C-10
Gas sensor value out of range (below 5 or above 250)
Moderate
Address soon - your appliance may not work properly
What This Means
Sensor disconnected; Faulty sensor connection; Defective gas sensor; Main PCB malfunction
How to Fix
- 1
Check sensor part and connection of sensor housing
- 2
Check PCB connector pins
- 3
If connections correct, replace cooking sensor
- 4
If problem persists, replace Main PCB
This Error Applies To
Samsung NQ70M7770D Series Ovens & Ranges
Related Error Codes
Keypad keys are shorted
Door lock is mispositioned
Communication between Main and Sub PCB is interrupted
Partition inserted or removed while oven is operating
Communication between Main and Touch PCB is interrupted
Steam sensor is open or shorted when steam mode is on
Water draining issue - water level sensor detects remaining water after maximum draining time
Cooling motor is operating abnormally