Error Code 81
Compressor will not start when the refrigerator powers on.
Critical
Stop using immediately - risk of damage or safety issue
Also displayed as: 81 (Freezer), c (Fridge)
What This Means
Short circuit between compressor U/V/W windings at CN04; Short circuit between IPM pins #1-26; IPM operation voltage dropped below DC13.5V; Compressor or refrigerant cycle issue
What actually causes this:
Compressor burned out, wiring is shorted, or control board failed.
First Thing to Check
Check that there is power reaching the compressor.
Parts Involved
How to Fix
- 1
Check for shorts at compressor CN04 connector
- 2
Verify IPM (Inverter Power Module) voltage is above 13.5V DC
- 3
Check compressor winding resistance