Error Code F-1-ô
Outside temperature sensor is not reporting correctly
Moderate
Address soon - your appliance may not work properly
Also displayed as: F-1-ô
What This Means
Sensor housing separation; Connector contact error; Sensor disconnection or open; Short circuit in sensor wiring; Temperature sensing out of valid range (>149°F or <-58°F)
What actually causes this:
Sensor got wet or connector corroded
First Thing to Check
Check inside top hinge for water or corrosion
Parts Involved
How to Fix
- 1
1. Check Main PCB Connector CN31 insertion
- 2
2. Verify Ambient Sensor unit is normal
- 3
3. Measure voltage between CN31-#1(White) and REG1, Heat Sink (should be 4.6V~0.6V)
- 4
4. Check IC10 MICOM #59 input voltage
- 5
5. Measure resistance CN31 #1 ´ #3 and compare with temperature table
This Error Applies To
Samsung RF195AC Series Refrigerators (2009) (2009–present)
Related Error Codes
Refrigerator defrost sensor is malfunctioning
Refrigerator section temperature sensor is not working properly
Ice maker temperature sensor has failed and needs replacement
Ice maker mechanism is not rotating or completing its cycle
Refrigerator fan is not spinning or not reporting rotation
Freezer temperature sensor is not working
Freezer defrost heater is not working or stuck on
Refrigerator defrost heating is not working or stuck on