Error Code F-1-6
The freezer defrost heater is not working, causing ice and frost to build up
Moderate
Address soon - your appliance may not work properly
Also displayed as: F-1-6 (LED blink pattern)
What This Means
Defrost heater housing separated; Heater contact error or disconnection; Heater short circuit; Temperature fuse error (bimetal); Defrost not completing within 70 minutes
What actually causes this:
The defrost heater burned out or the safety thermostat tripped and will not reset
First Thing to Check
Check for heavy ice buildup on the back wall or bottom of the freezer — this confirms a defrost problem
Parts Involved
How to Fix
- 1
1. Use self-diagnostic function to check error before power off
- 2
2. Use manual defrost (Fd mode) via test mode
- 3
3. Check defrost sensor temperature — should reach above 53.6°F (12°C) for freezer
- 4
4. Measure F DEF heater resistance at CN72 #7 (Brown) to #3 (Orange) — should be 66/240 ohm ±10%
- 5
5. Check for 0Ω (heater short) or ∞Ω (wire/bimetal open)
- 6
6. If heater is normal, check relay and replace PCB if needed
This Error Applies To
Samsung RF195AC Series Refrigerators (2009) (2009–present)
Related Error Codes
Refrigerator defrost sensor is malfunctioning
Refrigerator section temperature sensor is not working properly
Ice maker temperature sensor has failed and needs replacement
Ice maker mechanism is not rotating or completing its cycle
Refrigerator fan is not spinning or not reporting rotation
Freezer temperature sensor is not working
Freezer defrost heater is not working or stuck on
Refrigerator defrost heating is not working or stuck on