Error Code 60
Compressor will not start
Critical
Stop using immediately - risk of damage or safety issue
Also displayed as: F/R
What This Means
Short circuit between compressor phases; IPM (Inverter Power Module) voltage low; Inverter gate driver failure; Compressor winding shorted
What actually causes this:
Compressor winding is shorted or inverter board is broken
First Thing to Check
Listen for relay clicking sound when power is applied
Parts Involved
How to Fix
- 1
1. Check voltage at TD505: should be DC 15V
- 2
2. Check voltage at C125: should be DC 5V
- 3
3. Measure compressor winding continuity
- 4
4. Check IPM voltage output
- 5
5. Activate manual operation mode to test
This Error Applies To
Samsung RF22A4 Series Refrigerators (2021) (2021–present)
Related Error Codes
Control panel cannot talk to main circuit board
Main board cannot control the compressor
Freezer is not cold enough
Cannot detect compressor motor position
Inverter board is too hot
Humidity level cannot be monitored
Water in dispenser tank cannot be heated
Compressor protection circuit activated