Samsung Refrigerators2016–present

Error Code 44

Main board cannot communicate with compressor inverter

Critical

Stop using immediately - risk of damage or safety issue

Also displayed as: 44

What This Means

Communication cable disconnected or loose; Communication cable damaged or shorted; Inverter PCB defective; Main PCB defective; Connector pin corrosion

What actually causes this:

Communication cable came loose or inverter board failed

First Thing to Check

Check for loose cables at back of refrigerator — if all cables appear secure, call technician

Parts Involved

Main PCBInverter PCBCommunication CableSMPS Board

How to Fix

  1. 1

    1. Inspect communication cable connection between Main and Inverter PCB

  2. 2

    2. Reconnect cable firmly if loose

  3. 3

    3. Check cable for visible damage, pinching, or moisture

  4. 4

    4. Use oscilloscope to verify data signals on communication cable

  5. 5

    5. Check SMPS (power supply) voltage output to both boards

  6. 6

    6. If communication signals present but error persists, replace Inverter PCB

  7. 7

    7. If no signals, replace Main PCB

This Error Applies To

Samsung RF22K9581 Series Refrigerators (2016) (2016–present)

Service manual exact match: RF28K9580Service manual exact match: RF22K9581

Need more help with your Samsung refrigerators?