Samsung Refrigerators2016–present

Error Code 46

Control chip communication error on main board

Critical

Stop using immediately - risk of damage or safety issue

Also displayed as: 46

What This Means

I/O Expander chip defective; Main PCB communication circuit defective; SDA/SCL signal line shorted or damaged; Pull-up resistors defective

What actually causes this:

Main board component failure or manufacturing defect

First Thing to Check

Power cycle refrigerator by unplugging for 5 minutes and plugging back in

Parts Involved

Main PCBI/O Expander ChipPull-up ResistorsCommunication Lines

How to Fix

  1. 1

    1. Check Main PCB for visible damage or burned components

  2. 2

    2. Use oscilloscope to verify SDA and SCL signal lines

  3. 3

    3. Check pull-up resistor values (typically 4.7kΩ) with multimeter

  4. 4

    4. Measure voltage on SDA/SCL lines — should be high (~3.3V) at idle

  5. 5

    5. If pull-ups are correct but no signals, replace Main PCB

This Error Applies To

Samsung RF22K9581 Series Refrigerators (2016) (2016–present)

Service manual exact match: RF28K9580Service manual exact match: RF22K9581

Need more help with your Samsung refrigerators?