Samsung Refrigerators2016–present

Error Code 82

Compressor power module has failed or overheated

Critical

Stop using immediately - risk of damage or safety issue

Also displayed as: 82

What This Means

Inverter PCB soldering defects; IPM module overheating or defective; SMPS voltage insufficient; Short circuit in compressor winding or motor leads; Inverter protection activated due to overcurrent

What actually causes this:

Inverter board component failure or compressor failure

First Thing to Check

Compressor should hum when cooling cycle starts — if completely silent, call technician

Parts Involved

Inverter PCBIPM ModuleSMPS Board

How to Fix

  1. 1

    1. Check DC 15V power output from SMPS — should be at least 13.5V

  2. 2

    2. Inspect Inverter PCB for burned, swollen, or corroded components

  3. 3

    3. Check for visible solder joints that are cracked or cold

  4. 4

    4. Allow IPM module to cool for 30 minutes and try restarting

  5. 5

    5. If fault persists, replace Inverter PCB

This Error Applies To

Samsung RF22K9581 Series Refrigerators (2016) (2016–present)

Service manual exact match: RF28K9580Service manual exact match: RF22K9581