Error Code 82
Compressor power module has failed or overheated
Critical
Stop using immediately - risk of damage or safety issue
Also displayed as: 82
What This Means
Inverter PCB soldering defects; IPM module overheating or defective; SMPS voltage insufficient; Short circuit in compressor winding or motor leads; Inverter protection activated due to overcurrent
What actually causes this:
Inverter board component failure or compressor failure
First Thing to Check
Compressor should hum when cooling cycle starts — if completely silent, call technician
Parts Involved
How to Fix
- 1
1. Check DC 15V power output from SMPS — should be at least 13.5V
- 2
2. Inspect Inverter PCB for burned, swollen, or corroded components
- 3
3. Check for visible solder joints that are cracked or cold
- 4
4. Allow IPM module to cool for 30 minutes and try restarting
- 5
5. If fault persists, replace Inverter PCB
This Error Applies To
Samsung RF22K9581 Series Refrigerators (2016) (2016–present)
Related Error Codes
Freezer defrost sensor is not working
Freezer temperature sensor is not working
Outside temperature sensor is not working
Ice maker temperature sensor is not working
Refrigerator fan is not working
Convertible zone defrost system secondary error
Refrigerator compartment temperature sensor is not working
Convertible zone temperature sensor is not working