Error Code ⑮
The ice room temperature sensor isn't reading correctly
Critical
Stop using immediately - risk of damage or safety issue
Also displayed as: LED blinks in self-diagnostic checklist position 15
What This Means
Ice room thermistor disconnected; Wire harness damaged from ice storage area to Main PBA; Thermistor defective (open circuit or short); Main PBA defect
What actually causes this:
The ice room sensor wire came loose or sensor failed
First Thing to Check
Check if ice bucket empties normally — malfunction may indicate sensor/heater issue
Parts Involved
How to Fix
- 1
1. Measure voltage at MAIN PCB CN90 between pins 2 and 4 — must be 4.5V to 1.0V
- 2
2. Check connector at ice room sensor location
- 3
3. Disconnect CN90 and measure thermistor resistance (power off)
- 4
4. At 77°F (25°C), should read 5.0 kΩ
- 5
5. If resistance is normal, replace Main PBA
This Error Applies To
Samsung RF23R6 Series Refrigerators (2010) (2010–present)
Related Error Codes
The freezer temperature sensor isn't reading correctly
The outside temperature sensor isn't reading correctly
The refrigerator temperature sensor isn't reading correctly
The Cool Select Pantry temperature sensor isn't working
The ice room cooling fan isn't running
The freezer defrost sensor isn't reading temperature correctly
The ice maker temperature sensor isn't reading correctly
The freezer cooling fan isn't running