Samsung Refrigerators2009–present

Error Code F-1-6

Ice room compartment temperature sensor is out of range or faulty

Moderate

Address soon - your appliance may not work properly

Also displayed as: F-1-6 / F-10-2 (LED blink pattern on panel)

What This Means

Connector at CN31/CN76 loose or disconnected; Sensor reading above 149°F (65°C) or below -58°F (-50°C); Sensor wire open or shorted; Failed sensor unit

What actually causes this:

Ice room sensor connector worked loose or sensor failed from continuous cold cycling.

First Thing to Check

Re-seat the orange wire connector at CN31 pin 3 on the main board.

Parts Involved

Ice Room Sensor (502AT)Main PCB (CN31, CN76 connectors)

How to Fix

  1. 1

    Check MAIN PCB connectors CN31 and CN76 are fully seated

  2. 2

    Measure resistance between CN31 #3 (Orange) and CN76 #1 (Gray) — compare to DATA1 temperature table

  3. 3

    Measure voltage at CN31 #3 (Orange) vs REG1 HEAT SINK ground — should be 0.6V to 4.6V

  4. 4

    Check IC01 MICOM pin #71 input voltage

  5. 5

    Check SENSOR MARKING #8 (R308) on PCB

This Error Applies To

Samsung RF267AERS Series Refrigerators (2009) (2009–present)

Service manual exact match: RF26XAERS/XAAService manual exact match: RF267AFBP/XACService manual exact match: RF267AEBP/XAAService manual exact match: RF26XAEPN/XAAService manual exact match: RF267AERS/XAAService manual exact match: RF267AEPN/XAAService manual exact match: RF267AFRS/XACService manual exact match: RF267AEWP/XAA

Need more help with your Samsung refrigerators?