Error Code 86E
Home electrical supply voltage too high
Critical
Stop using immediately - risk of damage or safety issue
Also displayed as: 86 E
What This Means
Input AC voltage over 155V for 110-127V models; Input AC voltage over 310V for 220-240V models; Voltage regulator failure
What actually causes this:
Utility company overvoltage condition or transformer issue
First Thing to Check
Check outlet voltage with multimeter
Parts Involved
How to Fix
- 1
Check input AC voltage at power inlet
- 2
Measure voltage across resistors R309, R310, R311
- 3
Check for surge conditions on power line