Error Code C-FAN
Compressor cooling fan malfunction or failure
Critical
Stop using immediately - risk of damage or safety issue
Also displayed as: C-FAN
What This Means
Feed back signal line contact error; Motor wire separation; Motor failure
What actually causes this:
The cooling fan for the compressor is not running or not reporting proper speed
First Thing to Check
Check voltage at CN20 pins 22-24 with compressor running
Parts Involved
How to Fix
- 1
Measure voltage between Main PCB CN20 22PIN and 24PIN
- 2
Voltage should be 7V to 12V during operation
This Error Applies To
Samsung RS22T5561 Series Refrigerators
Related Error Codes
Freezer defrost cycle sensor malfunction
Communication failure between main control board and display panel
Freezer temperature sensor failure or malfunction
Inverter board cannot communicate with main control board
Refrigerator temperature sensor failure
Freezer fan motor not operating or not responding
Input/Output expander chip not communicating with main processor
Dispenser panel is not communicating with main control board