Samsung NE59M4310SSOvens & Range
Error Code C-30
PCB temperature sensor opened
Moderate
Address soon - your appliance may not work properly
What This Means
PCB NTC sensor failure; PCB damage; Main PCB failure
How to Fix
- 1
Disconnect power and open back cover
- 2
Remove PCB Main from holder
- 3
Measure NTC sensor resistance on backside of PCB (Normal: 3.8KΩ at room temperature)
- 4
If abnormal, replace PCB Main