Error Code C-70
Steam temperature sensor circuit open or shorted
Critical
Stop using immediately - risk of damage or safety issue
Also displayed as: C-70
What This Means
Steam sensor connector disconnected at Main PCB; Steam sensor connector disconnected at sensor; Open circuit in steam sensor wire harness; Short circuit in steam sensor wire harness; Defective steam temperature sensor; Main PCB failure
What actually causes this:
Broken sensor wire, water intrusion, or loose connector in steam circuit
First Thing to Check
Inspect steam sensor connector at Wall Main PCB (CN340)
Parts Involved
How to Fix
- 1
Check whether connector at the Main PCB has been inserted
- 2
Check whether connector at the sensor has been inserted
- 3
Check correct wiring between Wall Main PCB (CN340) and steam sensor
- 4
Measure steam sensor resistance