Error Code C-A2
Magnetron or convection cooling fan not operating correctly
Moderate
Address soon - your appliance may not work properly
Also displayed as: C-A2
What This Means
Cooling motor connector disconnected at Main PCB; Cooling motor connector disconnected at motor; Cooling motor malfunction; Defective cooling motor windings
What actually causes this:
Motor bearing failure, broken windings, or loose connection
First Thing to Check
Verify cooling motor connector is properly seated at Main PCB
Parts Involved
How to Fix
- 1
Check whether connector at the Main PCB has been inserted
- 2
Check whether connector at the motor has been inserted
- 3
Test cooling motor operation
- 4
Measure motor resistance and voltage
Other Error Codes for NQ70M7770DG