Error Code E gF
Defect of flow meter or lack of water supply — malfunction of flow meter. Check connection of flow meter and water supply.
Moderate
Address soon - your appliance may not work properly
Also displayed as: E gF
How to Fix
- 1
Step 1: Check flow sensor connector in the machine room for loose or damaged connection.
- 2
Step 2: Measure flow sensor resistance: Red wire to Black wire. Expected: 4 ~ 30 kΩ. If outside this range, replace flow sensor.
- 3
Step 3: Check water supply — verify saddle valve is fully open and water pressure is adequate.
- 4
Step 4: Check water filter condition. Replace if older than 6 months or if indicator is illuminated.
- 5
Step 5: Check water line for kinks or blockage.
- 6
Step 6: If flow sensor resistance is correct and water supply is adequate, replace Main PCB.
- 7
Step 7: If water pressure is low (less than 20 psi), advise customer to contact plumber.
Other Error Codes for LRYXC2606D
Defect of freezer sensor — short-circuit or disconnection of freezer sensor
Defect of ice-room sensor or ice maker sensor — short-circuit or disconnection
Defect of freezer defrost sensor — short-circuit or disconnection of defrost sensor
Defect of UVC LED — UVC LED disconnected or UVC LED failure. Check UVC LED connection.
Defect of room temperature sensor (RT sensor) — short-circuit or disconnection
Defect of humidity sensor — short-circuit or disconnection of humidity sensor
Defect of freezer craft ice maker sensor — short-circuit or disconnection of craft ice maker sensor
Defect of Mini Cubed ice maker kit — malfunction of Mini Cubed ice maker motor