Error Code 41E
Main control board cannot communicate with display panel
Critical
Stop using immediately - risk of damage or safety issue
Also displayed as: 41 E
What This Means
No response from panel within 10 seconds; Main board to panel communication line failure; Panel PCB defect
What actually causes this:
Ribbon cable between boards disconnects or control board fails
First Thing to Check
Verify ribbon cable connections between main board and panel
Parts Involved
How to Fix
- 1
Communication error check requires oscilloscope
- 2
Check after replacing Main or Panel PCB
- 3
PC Er error code will light up with alarm sound
Other Error Codes for RH25H5611SR
Refrigerator compartment temperature too warm
Compressor power supply internal module failure
Freezer defrost sensor malfunction or open circuit
Humidity sensor failure or circuit open
Ice maker sensor malfunction or open circuit
Condenser cooling fan motor failure or no speed feedback
Ice maker cannot eject ice cubes or crushed ice
Freezer defrost heater circuit fault or heater stuck on