Error Code 5E

Refrigerator defrost sensor malfunction or open circuit

Critical

Stop using immediately - risk of damage or safety issue

Also displayed as: 5 E

What This Means

Connector slipped out or open contact; Wire cut or short circuited; Abnormal temperature sensing

What actually causes this:

Sensor connector becomes loose or thermistor fails from defrost cycle stress

First Thing to Check

Verify CN30 #6 connection on main PCB

Parts Involved

Thermistor (Fridge Defrost)MAIN PCB CN30

How to Fix

  1. 1

    Check voltage between MAIN PCB CN30 #6 and #7

  2. 2

    Voltage should be within 4.5V to 1.0V range