Error Code 82E

Compressor power supply internal module failure

Critical

Stop using immediately - risk of damage or safety issue

Also displayed as: 82 E

What This Means

IPM internal failure; Overtemperature condition; Short circuit in power stage

What actually causes this:

Power surge damages IPM chip or compressor short kills module

First Thing to Check

Look for burn marks on inverter PCB around IPM chip

Parts Involved

Inverter PCB DA92-00215IPM Module

How to Fix

  1. 1

    Check IPM device for damage or burns

  2. 2

    Verify input voltage and ground connections

  3. 3

    Check for short circuits in compressor wiring

Need more help with your Samsung RH25H5611SR?