Error Code 41E

Main control board cannot communicate with display panel

Critical

Stop using immediately - risk of damage or safety issue

Also displayed as: 41 E

What This Means

No response from panel within 10 seconds; Main board to panel communication line failure; Panel PCB defect

What actually causes this:

Ribbon cable between boards disconnects or control board fails

First Thing to Check

Verify ribbon cable connections between main board and panel

Parts Involved

MAIN PCB DA92-00624Panel PCB

How to Fix

  1. 1

    Communication error check requires oscilloscope

  2. 2

    Check after replacing Main or Panel PCB

  3. 3

    PC Er error code will light up with alarm sound

Need more help with your Samsung RH25H5613SL?