Error Code 6E
Ambient temperature sensor failure
Moderate
Address soon - your appliance may not work properly
Also displayed as: 6E
What This Means
Connector slipped out or open contact; Wire cut or short-circuited; Abnormal sensing temperature above 50°C or below -50°C
What actually causes this:
Thermistor fails, connector gets wet, or wiring breaks
First Thing to Check
Check CN30 pin 1-2 voltage with multimeter
Parts Involved
How to Fix
- 1
Check voltage between MAIN PCB CN30 #1 and #2 should be 4.5V~1.0V
- 2
Inspect connector seating
- 3
Measure ambient temperature sensor resistance
- 4
Replace thermistor if abnormal