Error Code 13E
Humidity sensor failure
Minor
Usually easy to fix - may resolve on its own
Also displayed as: 13E
What This Means
Connector slipped out or open contact; Wire cut or short-circuited; Abnormal sensing value
What actually causes this:
Sensor fails from moisture exposure or connector corrosion
First Thing to Check
Check connector CN30 pin 11, ensure it's dry
Parts Involved
How to Fix
- 1
Check voltage between MAIN PCB CN30 #11 and #8 should be 4.5V~1.0V
- 2
Inspect connector seating
- 3
Measure humidity sensor resistance
- 4
Replace sensor if abnormal