Error Code 82E

Inverter power module internal fault

Critical

Stop using immediately - risk of damage or safety issue

Also displayed as: 82E

What This Means

IPM internal circuit fault; Over-current or over-temperature in IPM; Defective IPM module; Defective Inverter PBA

What actually causes this:

IPM overheats, overvoltage spikes damage circuit, or component solder joint fails

First Thing to Check

Check for burnt or discolored components on Inverter PCB

Parts Involved

Inverter PBAIPM (Inverter Power Module)

How to Fix

  1. 1

    Check IPM operating voltage (should be under 13.5V DC)

  2. 2

    Look for burnt components on Inverter PBA

  3. 3

    Check input voltage oscillation

  4. 4

    Verify compressor circuit connections