Error Code IE

Water Inlet Error — correct water level (24.6 kHz) not reached within 8 minutes after water is supplied, or preset water level not reached within 20 minutes.

Moderate

Address soon - your appliance may not work properly

What This Means

Air chamber or tube clogged; Inlet valve filter clogged with foreign material; Inlet valve connectors broken or loose; Inlet valve assembly resistance out of range (should be 0.8-1.2 kΩ); Connector to MAIN PWB assembly (NA2, NA4, BL3) disconnected; Incorrect electrical connection (wiring harness); Water level frequency below 24.6 kHz indicating overfill issue; Pressure switch failure

How to Fix

  1. 1

    Confirm IE is displayed on panel.

  2. 2

    Press WASH/RINSE and DELAY WASH buttons simultaneously and check if water level frequency is below 24.6 kHz. If YES → check air chamber and tube for clogging.

  3. 3

    If frequency is OK → check if filter inlet valve is clogged with foreign material. If YES → clean or replace the filter.

  4. 4

    If filter is OK → check if inlet valve connectors are broken or loose. If YES → reconnect or repair the connector.

  5. 5

    If connectors are OK → measure resistance between each terminal of inlet valve assembly. Expected: 0.8-1.2 kΩ (refer to section 9-5, inlet valve assembly). If resistance is out of range → replace the INLET VALVE ASSEMBLY.

  6. 6

    If resistance is OK → check voltage at inlet valve connector. Expected: 120 V AC at all terminals of INLET VALVE ASSEMBLY while power is on. If voltage is correct → replace the INLET VALVE ASSEMBLY.

  7. 7

    If voltage is not present → check if connector to MAIN PWB assembly (NA2, NA4, BL3) is disconnected or disassembled. If YES → reconnect or repair the connector.

  8. 8

    If connector is OK → verify electrical connection is correct per section 9-5 wiring diagram (page 41). If NOT correct → replace the MAIN HARNESS.

  9. 9

    If wiring is correct → after checking connector, press WASH/RINSE + DELAY WASH; if water level frequency is below 24.6 kHz → check the PRESSURE SWITCH.

  10. 10

    If all above are OK → replace the MAIN PWB ASSEMBLY.

  11. 11

    Installation safety checklist: verify no water tap leakage, no freezing, no hose entanglement, no water shortage, no hose shrinkage, no supply hose leakage.