Error Code tC1
The water temperature sensor is giving incorrect readings.
Moderate
Address soon - your appliance may not work properly
Also displayed as: tC1
What This Means
Washing temperature sensor fault; Faulty or incorrect connections of dry condensing sensor; Main PCB fault; Freezing in winter season; IPM temperature abnormally high
What actually causes this:
The temperature sensor connector has come loose from vibration, or the sensor itself has failed.
First Thing to Check
Unplug the washer for 5 minutes, then restart. If the error returns, call for service.
Parts Involved
How to Fix
- 1
1. Check connections for the washing heater temperature sensor connector
- 2
2. If washing heater temperature sensor has functional error, replace it
- 3
3. Check connections for dry heater temperature sensor connector (tC2)
- 4
4. Check for frozen water supply in winter
Parts Commonly Needed for This Error
OEM part numbers confirmed by retailers
Other Error Codes for WW22N6850QX
The main board and motor inverter have lost communication.
The washer cannot detect the water level correctly.
The washing machine motor is not spinning properly.
The motor is drawing too much power or not reaching the right speed.
The washer cannot pump the water out.
The control panel and the main computer board are not communicating.
The main computer and motor driver boards are not communicating.
The washer's WiFi module is not communicating with the main board.